Page 10 - Energy Recovery Ventilation
P. 10

Advantages of Installing Shinwoo Air Conditioning Heat Recovery Ventilation Units
          Improvement of Indoor Air Quality







                      Improvement of Indoor Air Quality and Energy Saving Measures




                                              Standard                     Air Sterilization and Deodorization Device
               Model Classification






           Comparison Criteria                                                                Photocatalyst UnitPhotocatalyst Unit

                     CO₂ and
                  Indoor Ventilation           100%                                    100%
               Power
                    Hazardous                  100%                                  50% Saving
                 Substance Removal
                               Dust: Removable
             Consumption
                               Odor: Partial removal when ventilated   Dust: Removable
            Air Purification Function   Harmful Substances: Partial removal during ventilation   Odor: Over 85% removal
                               Bacteria: Not removable                Harmful Substances: Over 90% removal
                                    Additional air purifier installation indoors   Bacteria: Over 90% removal
                                                                      Heat exchange efficiency has the effect of reducing
              Energy Recovery  None other than heat exchange efficiency  electric power energy
                                                                      by reducing product operation time.
                              Due to contamination of the heat exchanger (bacteria,   Minimizes contamination of the heat exchanger (bacteria,
             Maintenance Costs  odor, etc.),                          odor, etc.),
                              it must be replaced at certain operating intervals.  extending  the replacement cycle of the heat exchanger
                                                                      and filter.


             Expected Improvement Drawing on the Installation of a Photocatalyst Unit within the Duct







                        Photocatalyst Unit          Photocatalyst Unit                    Hazardous Substances






            Installation of a photocatalyst unit in the duct  The OH , O₂, H₂O₂ and other substances generated by the   Initial indoor pollution status
                                               0
                                         photocatalyst unit are introduced into the indoor environment.  (VOCs, HCHO, floating bacteria, odor)












                 After 6 hours of PHI operation    After 12 hours of PHI operation    After 1 day of PHI operation



           ENERGY RECOVERY VENTILATION  10