Page 50 - Fan Coil Unit
P. 50

FAN COIL UNIT / AIR CONDITIONING

















































            A product designed to minimize operational noise for
            a comfortable indoor environment




            Low-Noise,


            Ceiling Concealed Type




            NC Noise Curve

                          [NC Curve 1]                   [NC Curve 2]



                                                                                  ▶  For energy savings, installation of On/Off valves for
                                                                                    each product is recommended.
                                                                                    -  These control the flow in coordination with the
               Level (dB)
                                               Level (dB)
                                                                                     unit's operation, preventing condensation issues
                                                                                     during cooling, and reducing unnecessary
                                                                                     operation cycles of the circulation pump.  Option
                                                                                  ▶  Both central control and group control are available.
                          Frequency                       Frequency                 Option
                                                                                    -  Central control can be achieved through power
            ▶  NC (Noise Criteria) curve is a method of evaluating indoor noise based on the results of analyzing noise in 1:1 octave   line communication and RS-485 communication.
              bands. It is a noise standard determined based on the degree to which it is harmful to conversation.
            ▶  With the application of a newly developed BLDC motor and fan, operation noise and power consumption are   -  Group control of up to 16 units can be performed
                                                                                     using a wired remote controller.
              minimized.                                                          ▶  The use of UV lamps provides outstanding effects in
            ▶  It can be easily operated based on contact control using a rotary switch.  terms of sterilization, antibacterial properties, odor
            ▶  As it is installed inside the ceiling, you can effectively utilize indoor space.  removal, and addressing sick building syndrome.  Option
            ▶ Able to apply 4 Pipe configuration.  Option                           - Korean Patent Registration No. 10-1147406
       50